E30E042 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 46 circuits (42 branches, one 3-phase main, one neutral), two strips with 21 ea 100A solid-core CTs with 3/4" spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E084 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 92 circuits (84 branches, two 3-phase mains, two neutrals), four strips with 21 ea 100A solid-core CTs with 3/4" spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E142 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 46 circuits (42 branches, one 3-phase main, one neutral), two strips with 21 ea 100A solid-core CTs with 1" spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E184 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 92 circuits (84 branches, two 3-phase mains, two neutrals), four strips with 21 ea 100A solid-core CTs with 1" spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E224 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 28 circuits (24 branches, one 3-phase main, one neutral), two strips with 12 ea 100A solid-core CTs with 18mm spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E236 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 40 circuits (36 branches, one 3-phase main, one neutral), two strips with 18 ea 100A solid-core CTs with 18mm spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E242 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 46 circuits (42 branches, one 3-phase main, one neutral), two strips with 21 ea 100A solid-core CTs with 18mm spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E248 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 56 circuits (48 branches, two 3-phase main, two neutral), four strips with 12 ea 100A solid-core CTs with 18mm spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E272 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 80 circuits (72 branches, two 3-phase main, two neutral), four strips with 18 ea 100A solid-core CTs with 18mm spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30E284 Advanced Monitoring w/Ethernet: Voltage, Current, Power and Energy for 92 circuits (84 branches, two 3-phase main, two neutral), four strips with 21 ea 100A solid-core CTs with 18mm spacing, Modbus, BACnet & SNMP communications, 90–277VAC (L-N) |
![]() |
E30A042 Advanced Monitoring: Voltage, Current, Power and Energy for 46 circuits (42 branches, one 3-phase main, one neutral), two strips with 21 ea 100A solid-core CTs with 3/4" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A084 Advanced Monitoring: Voltage, Current, Power and Energy for 92 circuits (84 branches, two 3-phase mains, two neutrals), four strips with 21 ea 100A solid-core CTs with 3/4" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A142 Advanced Monitoring: Voltage, Current, Power and Energy for 46 circuits (42 branches, one 3-phase main, one neutral), two strips with 21 ea 100A solid-core CTs with 1" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A184 Advanced Monitoring: Voltage, Current, Power and Energy for 92 circuits (84 branches, two 3-phase mains, two neutrals), four strips with 21 ea 100A solid-core CTs with 1" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A224 Advanced Monitoring: Voltage, Current, Power and Energy for 28 circuits (24 branches, one 3-phase main, one neutral), two strips with 12 ea 100A solid-core CTs with 18mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A236 Advanced Monitoring: Voltage, Current, Power and Energy for 40 circuits (36 branches, one 3-phase main, one neutral), two strips with 18 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A242 Advanced Monitoring: Voltage, Current, Power and Energy for 46 circuits (42 branches, one 3-phase main, one neutral), two strips with 21 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A248 Advanced Monitoring: Voltage, Current, Power and Energy for 56 circuits (48 branches, two 3-phase mains, two neutrals), four strips with 12 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A272 Advanced Monitoring: Voltage, Current, Power and Energy for 80 circuits (72 branches, two 3-phase mains, two neutrals), four strips with 18 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30A284 Advanced Monitoring: Voltage, Current, Power and Energy for 92 circuits (84 branches, two 3-phase mains, two neutrals), four strips with 21 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B042 Intermediate Monitoring: Voltage, Current, Power and Energy for one 3-phase main and one neutral, Voltage and Current for 42 branch circuits, two strips of 21 ea 100A solid-core CTs with 3/4" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B084 Intermediate Monitoring: Voltage, Current, Power and Energy for two 3-phase mains and two neutrals, Voltage and Current for 84 branch circuits, four strips of 21 ea 100A solid-core CTs with 3/4" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B142 Intermediate Monitoring: Voltage, Current, Power and Energy for one 3-phase main and one neutral, Voltage and Current for 42 branch circuits, two strips of 21 ea 100A solid-core CTs with 1" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B184 Intermediate Monitoring: Voltage, Current, Power and Energy for two 3-phase mains and two neutrals, Voltage and Current for 84 branch circuits, four strips of 21 ea 100A solid-core CTs with 1" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B224 Intermediate Monitoring: Voltage, Current, Power and Energy for one 3-phase main and one neutral, Voltage and Current for 24 branch circuits, two strips of 12 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B236 Intermediate Monitoring: Voltage, Current, Power and Energy for one 3-phase main and one neutral, Voltage and Current for 36 circuits, two strips with 18 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B242 Intermediate Monitoring: Voltage, Current, Power and Energy for one 3-phase main and one neutral, Voltage and Current for 42 circuits, two strips with 21 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B248 Intermediate Monitoring: Voltage, Current, Power and Energy for two 3-phase mains and two neutrals, Voltage and Current for 48 circuits, four strips with 12 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B272 Intermediate Monitoring: Voltage, Current, Power and Energy for two 3-phase mains and two neutrals, Voltage and Current for 72 circuits, four strips with 18 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30B284 Intermediate Monitoring: Voltage, Current, Power and Energy for two 3-phase mains and two neutrals, Voltage and Current for 84 circuits, four strips with 21 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C042 Basic Monitoring: Current only for 42 branch circuits, one 3-phase main and one neutral, two strips of 21 ea 100A solid-core CTs with 3/4" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C084 Basic Monitoring: Current only for 84 branch circuits, two 3-phase mains and two neutrals, four strips of 21 ea 100A solid-core CTs with 3/4" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C142 Basic Monitoring: Current only for 42 branch circuits, one 3-phase main and one neutral, two strips of 21 ea 100A solid-core CTs with 1" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C184 Basic Monitoring: Current only for 84 branch circuits, two 3-phase mains and two neutrals, four strips of 21 ea 100A solid-core CTs with 1" spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C224 Basic Monitoring: Current only for 24 branch circuits, one 3-phase main and one neutral, two strips of 12 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C236 Basic Monitoring: Current only for 36 branch circuits, one 3-phase main and one neutral, two strips with 18 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C242 Basic Monitoring: Current only for 42 branch circuits, one 3-phase main and one neutral, two strips with 21 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C248 Basic Monitoring: Current only for 48 branch circuits, two 3-phase mains and two neutrals, four strips with 12 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C272 Basic Monitoring: Current only for 72 branch circuits, two 3-phase mains and two neutrals, four strips with 18 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
E30C284 Basic Monitoring:Current only for 84 branch circuits, two 3-phase mains and two neutrals, four strips with 21 ea 100A solid-core CTs with 18 mm spacing, Modbus communications, 90–277VAC (L-N) |
![]() |
H704-42 Current only monitoring, 50A,42 Circuit, 3/4" spacing, Modbus communications, 120VAC (L-N) |
![]() |
H704-42/1 Current only monitoring, 50A, 42 Circuit, 1" spacing, Modbus communications, 120VAC (L-N) |
![]() |
H704-42/1E Current only monitoring, 50A, 42 Circuit, 1" spacing, Modbus communications, 240 VAC (L-N) |
![]() |
H704-42E Current only monitoring, 50A, 42 Circuit, 3/4" spacing, Modbus communications, 240VAC (L-N) |
![]() |
H704-42H Current only monitoring, 100A, 42 Circuit, 3/4" Spacing, Modbus communications, 120VAC (L-N) |