The Veris direct insert style liquid flow sensor with stainless steel/PPS tip combines flow sensing with a built-in transmitter for an all-in-one flow measuring system. This device fits all 1-1/2” to 10” (38 to 254mm) pipes, and it is intended for direct installation into the pipe through a 1” tap. This sensor is available with or without hot tap capability. In the hot tap installation, the sensor is mounted in the pipe under pressure by attaching a service saddle or weld-on fitting to the pipe. Then the sensor assembly is attached to an isolation valve and extended into the pipeline to measure flow. Hot tap installations are often required in retrofit projects, but even in new construction, a hot tap sensor can be desirable for service considerations.

APPLICATIONS

  • Flow measuring projects
  • True hot tap installations

FEATURES

  • NEMA 4 electronics housing...rugged and weather-proof
  • Scaled pulse output
  • Viton® O-ring seal...no leaks
  • Stainless steel impeller, tungsten carbide shaft and polyamide-imide bearing...highly durable