The Hawkeye line of current sensors is widely acknowledged as the industry standard for proof of flow. Unlike mechanical switches, Hawkeye current sensors are solid state and do not suffer the failures caused by the wear and tear of moving parts. Veris offers a full range of current transducers and switches.

Current Switch

Binary output current sensors offering either an open or closed contact that changes state upon failure and on/off conditions.

H300 (Current Switch -Fixed Trip) Fixed Trip
Current Switches that change states as soon at perceptable current is present. Most commonly used to determine status on direct drive motors and other loads where on/off indication is desired.
Adjustable Trip Adjustable Trip
Current switches that allow the user to set the trip point at any point within the operating range of the sensor. Ideal for status on pump and belt driven fan motors where belt-loss/coupling shear are a concern.
H606 Current Switch Adjustable Trip, N.C. Out
Normally Closed current switches that allow the user to set the trip point at any point within the operating range of the sensor. Ideal for status on pump and belt driven fan motors where belt-loss/coupling shear are a concern.
H10F Fan Switch Auto Calibration, LV Out
Current switches that automatically adjust to detect most major motor failures.

Current Switch and Relay

Binary output current sensors with an integrated relay for contactor control. These devices combine the start/stop and status functions into a single labor and space saving device.

Fixed Trip Current Switch with Relay Fixed Trip
Current Switches that change states as soon at perceptable current is present. Most commonly used to determine status on direct drive motors and other loads where on/off indication is desired.
Adjustable Trip with Relay Current Switch (H735) Adjustable Trip
Current switches that allow the user to set the trip point at any point within the operating range of the sensor. Ideal for status on pump and belt driven fan motors where belt-loss/coupling shear are a concern.

Current Transducer

Analog output current sensors providing a signal corosponding to actual amperage draw of the monitored load. Provided in a wide range of amperages and available with convienient slide switch range selection.

4-20mA Out Current Transducer 4-20mA Out
Sensors providing a loop powered 4-20mA analog signal.
0-5VDC Out Current Transducers 0-5VDC Out
Sensors providing a self powered 0-5VDC analog signal.
0-10VDC Out Current Transducers 0-10VDC Out
Sensors providing a self powered 0-10VDC analog signal.

Current Transducer with Relay

Analog output current sensors with an integrated relay for contactor control. These devices combine the start/stop and status functions into a single labor and space saving device.

4-20mA Out Current Tranducer with Relay 4-20mA Out
Sensors providing a loop powered 4-20mA analog signal.
0-5VDC Out Current Transducer with Relay 0-5VDC Out
Sensors providing a self powered 0-5VDC analog signal.

Field Mount

Perfect for fractional horsepower motors such as small fans or recirculating pumps these devices combine the start/stop and status function in an eclosure optimized to save space in a handy-box or other electrical enclosure.

Motor Control Field Mounts Motor Control
Motor Control units designed to mount direclty to a 4x electrical box.
Status Relay Field Mount Status Relay
Motor control units designed to nipple mount to any 1/2" knockout.

AC Load Status

Variable Frequency Sensor

DC Current Transducer