Space-Efficient Crowbar Protection


MODEL:CB08



The MCG CB08 crowbar line addresses the need to protect low voltage microelectronics from damaging overvoltage events, usually caused by failing power supply regulation. Reacting to an overvoltage in just microseconds, the unit protects even the most sensitive circuits from damage. The CB08 series is available in wide range of standard trip voltages. They are epoxy encapsulated with a small footprint and a low-profile for easy OEM application.







Vtrip (standard voltages in DC volts): 3.0, 3.7, 4.1, 4.3, 4.7, 5.5, 6.4, 7.9, 10.4, 13.5, 14.5, 15.4, 16.4, 18.4, 20.4, 22.4, 24.4, 26.4, 30.4, 32.4, 36.4, 40.4, 44.4, 48.4, 54.4, 60.4, 66.4, 72.4, 100, 120, 147, 167, 200, 220, 247, 287, 300, 340, 360



Vtrip tolerance: (T= 25oC (77oF)): +/- 5 %

(T= -10o to +60oC (14o to +140oF)): +/- 10 %


Response time: Less than 5 microseconds


I leakage (T= 25oC (77oF)) Vt = 3.0 thru 10.4V: < 6mA @ V = Vt – (10% Vt)

Vt > 10.4V: < 50 μA @ V = Vt – (10% Vt)


IDC Max: 20A


Hold Current (T= 25oC (77oF)): 18mA Typical, 40mA Max


Temperature (Operating/Storage): -40o to +70o C/-40o to +85o C (-40o to +158o F/-40o to +185oF)


Construction: Epoxy encapsulated, DAP (diallyl ortho phthalate) enclosure


Dimensions, Enclosure: 1.4”L x 0.9”W x 0.68”H (35.6mm L x 22.9mm W x 17.3 mm H)


Terminals: 0.255”L, 0.040”d (6.5mm L, 1.0mm d)


Model Buildup: CB08-20A/xxxVDC where xxx is the desired Vtrip. Example: CB08-20A/200VDC


APPLICATION NOTE: For most common applications, choose the crowbar with the highest trip voltage (Vtrip) that the load can withstand continuously without damage. Vtrip must be greater than the maximum voltage (DC or peak) that the power supply provides nominally.


Example: Load is powered by 5VDC. Maximum power supply output is 5.5VDC during normal operation. Load can safely withstand 7.0 VDC continuously. Choose model with Vtrip = 6.4VDC.


Related models: LVC Series