U001-0005
- Temperature Rating 105°C (221°F) continuous
- Pressure Rating At 38°C (100°F) 225BR: 300psi; 226BR/226SS: 400psi; At 105°C (221°F) 225BR: 210psi; 226BR: 250 psi; 226SS: 300 psi
- Wetted Materials UHMW-PE bearing, polyamide impeller, tungsten carbide shaft, EPDM O-rings
- Accuracy ±1.0% of full scale over recommended design flow range; ±4.0% of reading within calibration range*
- Repeatability ±0.3% of full scale over recommended design flow range*
- Linearity ±0.2% of full scale over recommended design flow range*
- Transducer Excitation Quiescent current 600uA@8VDC to 35VDC max.; Quiescent voltage (Vh)=Vsupply - (600mA*Zsupply); On-State (Vlow) Max 1.2VDC@40mA current limit (15 O overall+0.7VDC)
- Output Frequency 3.2Hz to 200 Hz
- Output Pulse Width 5 msec ±25%
* =10 upstream and =5 downstream straight pipe diameters, uninterrupted flow.